Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Retina ; 44(5): 923-927, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38109723

RESUMEN

PURPOSE: To demonstrate through a diagnostic test used as a new preoperative assessment that trocar insertion for pars plana vitrectomy could be safely placed at a distance >4.0 mm in highly myopic eyes to facilitate the surgical maneuvers. METHODS: Thirty eyes of 30 patients were tested with a biometer for the axial length measurement and with ultrasound biomicroscopy to measure the pars plana length. Pars plana lengths of highly myopic eyes were then compared with those of emmetropic eyes. The surgeon also measured the pars plana of highly myopic eyes intraoperatively and compared it with ultrasound measurements to assess ultrasound biomicroscopy reliability. RESULTS: The mean axial length was 23.81 mm (SD ± 0.30) in the control group and 31.11 mm (SD ± 0.56) in the myopic group. The mean pars plana length was 4.96 mm (SD ± 0.19) in control eyes and 6.65 (SD ± 0.36) in myopic eyes. An extremely significant statistical difference ( P < 0.001) was obtained by comparing the length of pars plana between control eyes and myopic eyes. The results of pars plana measurements were 6.65 mm (SD ± 0.36, ultrasound biomicroscopy) and 6.66 mm (SD ± 0.34, intraoperative measurements) in myopic eyes. The statistical comparison of the measurements in these two groups did not give a statistically significant result ( P = 0.950). CONCLUSION: Ultrasound biomicroscopy is a reliable technique to calculate the length of pars plana in highly myopic eyes, where this parameter is significantly greater than that of emmetropic eyes. Trocars insertion for pars plana vitrectomy may be performed, in eyes with axial length >30 mm, in relative safety at a distance to limbus higher than 4 mm.


Asunto(s)
Longitud Axial del Ojo , Microscopía Acústica , Miopía Degenerativa , Vitrectomía , Humanos , Vitrectomía/métodos , Femenino , Masculino , Persona de Mediana Edad , Longitud Axial del Ojo/diagnóstico por imagen , Longitud Axial del Ojo/patología , Miopía Degenerativa/cirugía , Anciano , Adulto , Instrumentos Quirúrgicos , Reproducibilidad de los Resultados , Biometría/métodos
2.
Retin Cases Brief Rep ; 18(1): 18-23, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-35944558

RESUMEN

PURPOSE: This case report describes an innovative procedure for addressing retinal detachment in patients with morning glory syndrome. METHODS: An 18-year-old woman with unilateral morning glory syndrome complicated by macula-off retinal detachment without any visible peripheral retinal breaks underwent three corrective surgeries. In the first surgery, a 25-gauge pars plana vitrectomy with a 3-mm human amniotic membrane patch positioned on the optic disc and gas endotamponade was performed. When the gas reabsorbed, inferior retinal detachment recurred, and a second vitrectomy with silicone oil endotamponade was conducted. At three months, the retina was still attached under the silicone oil, so the oil was removed. At the second follow-up, retinal detachment had recurred, and a third vitrectomy with a larger amniotic patch and silicone oil endotamponade was performed. RESULTS: Three months following the last surgery, the subretinal fluid had totally reabsorbed, and the retina was completely attached. The best-corrected visual acuity was 20/100. CONCLUSION: To the best of our knowledge, the first description of a human amniotic patch associated with vitrectomy in morning glory syndrome complicated with retinal detachment is described. Using human amniotic membranes, positioned onto the optic nerve, and silicone oil endotamponade could be useful for morning glory syndrome complicated by retinal detachment.


Asunto(s)
Desprendimiento de Retina , Femenino , Humanos , Adolescente , Desprendimiento de Retina/diagnóstico , Desprendimiento de Retina/etiología , Desprendimiento de Retina/cirugía , Amnios , Aceites de Silicona , Agudeza Visual , Retina , Vitrectomía/métodos , Síndrome , Recurrencia , Estudios Retrospectivos
3.
Eur J Ophthalmol ; : 11206721231212545, 2023 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-37920982

RESUMEN

PURPOSE: To evaluate three months follow-up of SING IMT implant in patients affected by late-stage AMD. DESIGN: Prospective cohort study. SUBJECTS: In a total of 80 eyes of 40 patients who underwent the enrollment tests, 11 patients' eyes affected by late-stage AMD matched the inclusion criteria and underwent SING IMT implant from February to June 2022. METHODS: Before surgery, each patient underwent the enrollment examination to verify inclusion and exclusion criteria. MAIN OUTCOME MEASURES: BCVA for distance and for near, IOP, ACD and ECD were evaluated at 1 and 3 months follow up. Also quality of life in doing the activities of daily life was evaluated. RESULTS: BCVA for distance and for near improved from baseline to 3 months follow up (23.91 ± 9.418 ETDRS letters and 59.09 ± 11.58 ETDRS letters respectively (p < 0.001). An endothelial cell loss was shown (p < 0.001), with a rate of cell density reduction around 8.3% (baseline vs 3 months). CONCLUSIONS: SING IMT could be a valid surgical device to improve patients' sight and quality of life which have been deteriorated by late-stage macular degeneration. Further studies with more patients and longer follow up are needed to confirm our results.

4.
J Pers Med ; 13(6)2023 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-37373893

RESUMEN

Fabry disease (FD) is an X-linked lysosomal storage disorder, causing Gb-3 (globotriaosylceramide) buildup in cellular lysosomes throughout the body, in particular in blood vessel walls, neuronal cells, and smooth muscle. The gradual accumulation of this glycosphingolipid in numerous eye tissues causes conjunctival vascular abnormalities, corneal epithelial opacities (cornea verticillata), lens opacities, and retinal vascular abnormalities. Although a severe vision impairment is rare, these abnormalities are diagnostic indicators and prognostics for severity. Cornea verticillata is the most common ophthalmic feature in both hemizygous men and heterozygous females. Vessel tortuosity has been linked to a faster disease progression and may be useful in predicting systemic involvement. New technologies such as optical coherence tomography angiography (OCTA) are useful for monitoring retinal microvasculature alterations in FD patients. Along with OCTA, corneal topographic analysis, confocal microscopy, and electro-functional examinations, contributed to the recognition of ocular abnormalities and have been correlated with systemic involvement. We offer an update regarding FD ocular manifestations, focusing on findings derived from the most recent imaging modalities, to optimize the management of this pathology.

5.
Int Ophthalmol ; 43(9): 3035-3044, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37031312

RESUMEN

PURPOSE: The aim this study is to determine anterior chamber parameters variations induced by PreserFlo MicroShunt implantation, in the early post-operative days. METHODS: This is a prospective observational study on 48 eyes undergoing PreserFlo MicroShunt implantation alone (n = 30) or combined with phacoemulsification (n = 18). Anterior chamber depth (ACD) and volume (ACV), central corneal thickness (CCT) and total corneal astigmatism (TCA) were evaluated pre-operatively, post-operatively at day-1 and at 1 week with the Pentacam tomography. RESULTS: Intraocular pressure decreased significantly from 20.9 ± 4.0 to 8.0 ± 2.8 mmHg (p < 0.0001) and to 10.8 ± 3.7 mmHg (p = 0.0001) at day-1 and week-1, respectively. TCA varied significantly from baseline (1.5 ± 1.2 D) to both day 1 follow up (2.7 ± 1.9 D, p = 0.0003) and week 1 follow up (2.2 ± 1.6 D, p = 0.02). Nevertheless, only K1 showed a transient flattening at day 1, while K2 value didn't show any statistical variation in the early post-operative period. CCT value rose significantly at day 1 (547 ± 49 vs. 529 ± 32 µm at baseline, p = 0.04), but then returned toward pre-operative values at week 1 (537 ± 39 µm, p = 0.57). In contrast, ACD values changed insignificantly from 3.3 ± 0.9 to 3.7 ± 1.0 mm at day 1 (p = 0.21), and then stabilized at 3.4 ± 0.9 mm (p = 0.82) at week 1 follow up. ACV changed from 150.0 ± 36.2 to 159.5 ± 42.1 mm3 at day 1 (p = 0.58), and successively to 153.9 ± 37.9 mm3 at week 1 follow up (p = 0.96). The subgroup analysis in eyes undergoing standalone PreserFlo implantation didn't show significant changes in both ACD and ACV. CONCLUSION: PreserFlo implantation minimizes the anterior chamber modifications generated by traditional filtering surgery, inducing low and transient corneal and biometric changes only in the very early postoperative period and insignificant changes to ACD and ACV, label of its safety and minimal invasiveness.


Asunto(s)
Extracción de Catarata , Glaucoma de Ángulo Abierto , Humanos , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/cirugía , Cámara Anterior/diagnóstico por imagen , Córnea/cirugía , Extracción de Catarata/métodos , Presión Intraocular , Periodo Posoperatorio
6.
Retina ; 43(2): 173-181, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36228144

RESUMEN

PURPOSE: To predict improvement of best-corrected visual acuity (BCVA) 1 year after pars plana vitrectomy for epiretinal membrane (ERM) using artificial intelligence methods on optical coherence tomography B-scan images. METHODS: Four hundred and eleven (411) patients with Stage II ERM were divided in a group improvement (IM) (≥15 ETDRS letters of VA recovery) and a group no improvement (N-IM) (<15 letters) according to 1-year VA improvement after 25-G pars plana vitrectomy with internal limiting membrane peeling. Primary outcome was the creation of a deep learning classifier (DLC) based on optical coherence tomography B-scan images for prediction. Secondary outcome was assessment of the influence of various clinical and imaging predictors on BCVA improvement. Inception-ResNet-V2 was trained using standard augmentation techniques. Testing was performed on an external data set. For secondary outcome, B-scan acquisitions were analyzed by graders both before and after fibrillary change processing enhancement. RESULTS: The overall performance of the DLC showed a sensitivity of 87.3% and a specificity of 86.2%. Regression analysis showed a difference in preoperative images prevalence of ectopic inner foveal layer, foveal detachment, ellipsoid zone interruption, cotton wool sign, unprocessed fibrillary changes (odds ratio = 2.75 [confidence interval: 2.49-2.96]), and processed fibrillary changes (odds ratio = 5.42 [confidence interval: 4.81-6.08]), whereas preoperative BCVA and central macular thickness did not differ between groups. CONCLUSION: The DLC showed high performances in predicting 1-year visual outcome in ERM surgery patients. Fibrillary changes should also be considered as relevant predictors.


Asunto(s)
Membrana Epirretinal , Humanos , Membrana Epirretinal/diagnóstico , Membrana Epirretinal/cirugía , Inteligencia Artificial , Estudios Retrospectivos , Agudeza Visual , Retina , Tomografía de Coherencia Óptica/métodos , Vitrectomía/métodos
7.
Int Ophthalmol ; 43(4): 1207-1214, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36129605

RESUMEN

PURPOSE: The aim of this study is to investigate changes in choroidal and optic nerve morphological parameters following MicroShunt PreserFlo implantation. The secondary aim is to investigate how the structural changes relate to the decrease in intraocular pressure (IOP). METHODS: Prospective observational study on 15 eyes with glaucoma requiring MicroShunt implantation. Optical coherence tomography was used to measure macular choroidal thickness (MCT), peripapillary choroidal thickness (PCT), lamina cribrosa depth (LCD), cup depth and prelaminar tissue thickness (PLT), before and one day after surgery. Results were expressed in median and interquartile range (IQR) and correlated with IOP results. RESULTS: The IOP decreased from a median of 25 (IQR = 11) mmHg to 8 (IQR = 2) mmHg the day after surgery. Median MCT increased after MicroShunt implantation from 252.1 (IQR = 156.4) µm to a postoperative value of 318.1 (IQR = 166.6) µm (p < 0.001), with a median increase of + 87.7 µm (+ 26.4%). PCT increased from 157.2 (IQR = 109.1) µm before surgery to 206.0 (IQR = 136.1) µm after surgery (p < 0.001). Moreover, we found a significant post-operative decrease in cup depth (median reduction of - 29.3 µm, p < 0.001) and an increase in PLT (median increase of 27.3 µm, p = 0.028). On the other side, LCD reduction 24 h after surgery didn't reach any statistical significance. CONCLUSION: PreserFlo implantation determines retinal structural changes which appear similar to those caused by traditional filtering surgery, confirming the effectiveness of this device, meantime carrying a much smaller complications rate when compared to trabeculectomy.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Disco Óptico , Humanos , Glaucoma de Ángulo Abierto/cirugía , Coroides , Presión Intraocular , Tomografía de Coherencia Óptica/métodos
8.
Retina ; 43(11): 2034-2036, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34731095

RESUMEN

PURPOSE: To describe and evaluate the effectiveness of the modified Carlevale intraocular lens (IOL) fixation technique, using two vitrectomy ports as lens plug fixation sites. MATERIALS AND METHODS: This prospective, consecutive, interventional study examined 60 eyes in 60 patients, who underwent 25- or 23-gauge vitrectomy for an IOL subluxation/luxation, lens dislocation, or aphakia, with Carlevale IOL implantation. RESULTS: Postoperatively, transient ocular hypotension was observed in four eyes. The mean refractive prediction error was -0.27 ± 0.78 diopters. No postoperative complications, such as retinal detachment, endophthalmitis, or IOL dislocation, were observed in the 4-month follow-up. CONCLUSION: This new technique may be simple, fast, and effective because of fewer scleral wounds and fewer postoperative complications.


Asunto(s)
Subluxación del Cristalino , Lentes Intraoculares , Humanos , Implantación de Lentes Intraoculares/métodos , Vitrectomía/métodos , Estudios Prospectivos , Esclerótica/cirugía , Agudeza Visual , Subluxación del Cristalino/cirugía , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Técnicas de Sutura
9.
Can J Ophthalmol ; 58(2): 162-167, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-34562380

RESUMEN

OBJECTIVE: To compare surgical efficiency, visual and physical comfort, and safety profile of the ARTEVO 800 Digital Microscope (Carl Zeiss Meditec AG, Jena, Germany) and the Ngenuity 3D Visualization System (Alcon Laboratories Inc, Fort Worth, TX) in cataract surgery. DESIGN: Cross-sectional study. PARTICIPANTS: One hundred consecutive phacoemulsification cataract surgeries performed by five surgeons from June 1, 2020, to November 1, 2020. METHODS: For each case, the surgeons answered a 2-section questionnaire (before and after intervention) to collect data on cataract severity or grade, surgical risk, chosen three-dimensional (3D) visualization system, surgical complications, and the visual or physical discomfort experienced during the procedure. RESULTS: Each of the 5 surgeons performed 20 surgeries (N = 100) using either the ARTEVO 800 Digital Microscope (N = 50) or the Ngenuity Visualization System (N = 50). Mean duration of the surgical procedure was 17.07 ± 4.80 minutes, and none of the surgeons ever switched to the classical microscope. In addition, 40% of surgeries were considered at low risk, 30% at intermediate risk, and 30% at high risk. The Zoom, Focus, and XY commands were used 1-3 times, respectively, during 76 (p = 0.34), 73 (p = 0.49), and 76 (p = 0.64) interventions. Surgical uncertainty and operative fluency were similar using both systems (p = 0.53 and p = 0.19). We observed 14 intraoperative complications, 9 using Ngenuity and 5 using the ARTEVO 800. Surgeon's visual comfort (p = 0.79), colour or brightness perception (p = 0.82), and visual impairment (p = 0.62) during surgery were similar for both systems. Headache, backache, and other musculoskeletal problems were reported, respectively, after 14 (p = 0.79), 11 (p = 0.99), and 8 (p = 0.44) procedures. CONCLUSION: Both the Ngenuity 3D Visualization System (Alcon Laboratories Inc) and the ARTEVO 800 Digital Microscope (Carl Zeiss Meditec AG) provided comparable operative speed and overall surgical comfort during cataract surgery.


Asunto(s)
Catarata , Facoemulsificación , Humanos , Facoemulsificación/métodos , Imagenología Tridimensional/métodos , Tomografía de Coherencia Óptica , Estudios Transversales
10.
Retina ; 43(10): 1797-1801, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34009184

RESUMEN

PURPOSE: We propose a new releasable 8.0 polypropylene suture for leaking sclerotomies at the end of vitrectomy. Characteristic of this suture is that it can be easily removed the day after surgery at the slit-lamp examination. METHODS: Patients undergoing 23-gauge pars plana vitrectomy with the need for at least 2 sclerotomy sutures and having a preoperative Ocular Surface Disease Index score <12 were consecutively allocated to sealing with either polyglactin 910 absorbable suture (VY GROUP) or nonabsorbable 8.0 polypropylene releasable suture (PR GROUP). Evaluation of adverse events, Ocular Surface Disease Index score, and conjunctival hyperemia (through the Efron scale) was performed at 1, 7, and 30 days postoperatively. RESULTS: Both methods effectively sealed sclerotomies. PR GROUP showed a significantly lower Ocular Surface Disease Index score and lower degree of conjunctival hyperemia at both 7 and 30 days follow-up. The Ocular Surface Disease Index score decreased significantly after 7 days in PR GROUP while in VY GROUP improved at 30 days postoperatively. PR GROUP showed a lower degree of conjunctival hyperemia both at 7 and 30 days follow-up. CONCLUSION: Polypropylene 8-0 releasable sutures proved to be effective in 23-gauge pars plana vitrectomy wound sealing while inducing less ocular surface inflammation and patient discomfort compared with the standard polyglactin 910 suture.


Asunto(s)
Hiperemia , Esclerostomía , Humanos , Vitrectomía/métodos , Polipropilenos , Esclerostomía/métodos , Poliglactina 910 , Hiperemia/etiología , Hiperemia/cirugía , Esclerótica/cirugía , Técnicas de Sutura
11.
Retina ; 43(10): 1811-1815, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34101694

RESUMEN

PURPOSE: To describe and evaluate the effectiveness of wedge-shaped sclerotomies to close 25-gauge and 23-gauge transconjunctival pars plana vitrectomies. MATERIALS AND METHODS: This prospective, consecutive, interventional study examined 50 eyes of 50 patients who underwent 25-gauge and 23-gauge vitrectomy with wedge-shaped sclerotomies. RESULTS: The number of eyes requiring a wedge shape for sclerotomy closure and sclerotomies requiring sutures was collected. Three eyes had hypotony on Day 1. No statistically significant difference was observed between preoperative intraocular pressure and postoperative intraocular pressure on Days 15 and 30. No postoperative complications were observed during the follow-up period. CONCLUSION: The wedge-shaped sclerotomy is a simple, fast, and effective technique that does not require extra surgical materials and could be applied to microincision vitrectomy.


Asunto(s)
Esclerostomía , Vitrectomía , Humanos , Vitrectomía/métodos , Esclerostomía/métodos , Estudios Prospectivos , Técnicas de Sutura , Esclerótica/cirugía , Microcirugia/métodos
12.
Jpn J Ophthalmol ; 66(6): 518-526, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36301445

RESUMEN

PURPOSE: To determine the efficacy of using a human amniotic membrane to close macular hole retinal detachment in highly myopic eyes. STUDY DESIGN: Prospective, consecutive, nonrandomized interventional study. METHODS: We included 19 high myopic eyes from 19 patients affected by macular hole retinal detachment who had already undergone vitrectomy with internal limiting membrane peeling. The patients underwent vitrectomy with amniotic membrane transplant. RESULTS: Primary success was achieved after 3 months in 89.5% (17 of 19 eyes) and final macular hole closure was obtained in 94.7% (18 of 19 eyes) of the patients. The final retinal reattachment rate was 100%. The final 12-month mean BCVA improved from 20/2000 (2 logMAR) to 20/250 (1.1 logMAR). OCT-angiography revealed a high correlation between the superficial and deep capillary plexus and the final BCVA. CONCLUSION: Human amniotic membrane patches can effectively repair macular hole retinal detachment in high myopic eyes in terms of anatomic results and BCVA recovery.


Asunto(s)
Miopía Degenerativa , Desprendimiento de Retina , Perforaciones de la Retina , Humanos , Perforaciones de la Retina/diagnóstico , Perforaciones de la Retina/etiología , Perforaciones de la Retina/cirugía , Desprendimiento de Retina/diagnóstico , Desprendimiento de Retina/etiología , Desprendimiento de Retina/cirugía , Estudios Prospectivos , Amnios , Miopía Degenerativa/complicaciones , Miopía Degenerativa/diagnóstico , Agudeza Visual , Estudios Retrospectivos , Vitrectomía/métodos , Membrana Basal/cirugía , Tomografía de Coherencia Óptica
13.
Vision (Basel) ; 6(3)2022 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-35893755

RESUMEN

Background: To investigate macular microvascular changes after uncomplicated phacoemulsification surgery according to the cataract severity grade. Methods: Retrospective, cross-sectional study involving 23 eyes of 23 patients who underwent elective cataract extraction. All patients underwent routine ophthalmologic examination, including optical coherence tomography angiography (OCTA) at baseline (preoperative visit, T0) and seven days postoperatively (T7). OCTA scans were obtained with the spectral domain system Cirrus 5000 (Carl Zeiss Meditec, Inc., Dublin, CA, USA), and 3 mm × 3 mm raster fovea-centered scans were obtained to evaluate the superficial capillary plexus (SCP) vessel density, perfusion density, and foveal avascular zone (FAZ) parameters. Results: SCP perfusion density significantly increased from 28.3 ± 5.73% to 33.74 ± 4.13% after the surgery (p < 0.001). Similarly, SCP vessel density significantly increased from 15.14 ± 3.41 mm−1 to 18.14 ± 2.57 mm−1 after surgery (p < 0.001). The mean preoperative FAZ area significantly increased from 0.27 ± 0.12 mm to 0.24 ± 0.11 mm seven days postoperatively (p = 0.008). When comparing softer and harder cataracts, no significant variations in SCP vessel density, as well as SCP perfusion density parameters and the FAZ area, perimeter, and circularity index, were noted before and after surgery. Conclusions: Macular SPC vessel density and macular SCP perfusion density increase after uncomplicated cataract surgery regardless of the cataract severity.

14.
Vision (Basel) ; 6(2)2022 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-35645380

RESUMEN

BACKGROUND: Endothelial cells damage and thromboinflammation are considered key elements in the generation of organ impairment in patients with COVID-19 disease. The endothelial function is evaluated by measuring flow-mediated dilation (FMD). We aimed to analyze the association between FMD impairment and retinal vascular parameters in early post-COVID-19 patients. 00118-00199Tomography (OCT), OCT Angiography (OCTA) and slit lamp examination were performed. FMD ≤ 7% was considered as pathological. Our primary outcome was to assess potential differences in the radial peripapillary capillary plexus flow index (RPCP-FI) and RPCP density (RPCP-D) values between post-COVID-19 patients with and without FMD impairment. The associations of other retinal vascular parameters with FMD impairment were assessed as secondary endpoints. RESULTS: FMD impairment was detected in 31 patients (37.8%). RPCP-FI (p = 0.047), age (p = 0.048) and prevalence of diabetes (p = 0.046) significantly differed in patients with FMD ≤ 7% in regression analysis. RPCP-FI was linearly correlated with FMD values (R = 0.244, p =0.027). SCT was found to be lower in patients with impaired FMD (p = 0.004), although this difference was only a trend in binary logistic regression output (p = 0.07). CONCLUSIONS: Early post-COVID-19 patients showed a higher prevalence of FMD impairment compared to the general population. Age, diabetes and RPCP-FI were independently correlated with the presence of endothelial impairment in the early post-infective period.

15.
Ophthalmol Retina ; 6(10): 971-972, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35605958

RESUMEN

Age-related macular degeneration is the third leading cause of blindness worldwide after cataracts and glaucoma. We described our recent surgical experience in managing the smaller-incision, new-generation, implantable, miniature telescope that has been designed to enlarge retinal images of the central visual field implanted monocularly in the capsular bag after lens extraction.


Asunto(s)
Extracción de Catarata , Lentes Intraoculares , Degeneración Macular , Telescopios , Humanos , Degeneración Macular/diagnóstico , Degeneración Macular/cirugía
16.
Diagnostics (Basel) ; 12(5)2022 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-35626405

RESUMEN

Background: The purpose of this study is to compare the morphology of six-month follow-up blebs created by a subconjunctival glaucoma surgical device (XEN45) to those created by a PreserFlo MicroShunt with a sub-Tenon insertion, utilizing AS-OCT. Methods: A retrospective study of 29 eyes who underwent XEN45 implantation and 29 eyes who underwent PreserFlo MicroShunt implantation. The patients were analyzed at 24 h, 1 week, 1 month, 3 months and 6 months. At each visit, the maturation and morphological alterations of the blebs were observed, as well as connections with the IOP. Results: In both groups, IOP showed significant reduction at all follow ups (p < 0.0001). In XEN group, the most common bleb morphology in the immediate postoperative was the subconjuntival separation type (42%) followed by the uniform type (34%), with a trend inversion at 6 month follow up (51% of uniform type). On the contrary, the most common morphology after PreserFlo was the multiple internal layer (55%), which showed a tendency to reduce over time and was substituted by the microcystic multiform, whose percentage increased over time (17% at day 1 vs. 44% at month 6). Uniform appearance was associated by the posterior episcleral fluid (PEF) lake presence. Both horizontal and vertical diameters significantly increased over time. Conclusion: XEN and PreserFlo implantation resulted in the production of diffuse blebs with different characteristics, which may influence IOP lowering capacity and bleb revisions necessity over time.

17.
Vision (Basel) ; 6(2)2022 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-35466272

RESUMEN

Myopia is becoming more common across the world, affecting approximately two billion people and rising. Different kinds of therapies (optical, pharmaceutical, environmental, or behavioral) have been proposed to decrease myopia progression, but with variable results and a lack of standardization. The evidence that targeted myopic defocus inhibits eye length growth has paved the way for several contact and spectacle lense designs to induce a peripheral defocus, thus slowing myopia progression, but the perfect configuration has yet to be defined. One of the newest and more promising approaches in this field is the use of Defocus Incorporated Multiple Segments (DIMS) lenses. These lenses are built from the assumption that targeted myopic defocus, produced by 396 mid-peripheral lenslets with positive power, inhibits eye length growth. Recent studies have highlighted the effectiveness of these lenses compared to children who had worn single vision spectacle lenses, in terms of myopia control and tolerability. Despite the evidence that these lenses can help slow down the progression of myopia, the occasional mid-peripheral aberrations they can induce, as well as the overall eye strain that comes with wearing them, should not be overlooked. The aim of this review is to give attention to the advantages and the shortfalls of this new approach and to evaluate its effectiveness in clinical practice.

18.
Clin Ophthalmol ; 16: 1069-1084, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35418741

RESUMEN

Pars plana vitrectomy has become the standard procedure for primary macular holes (MHs) repair, including the removal of the posterior cortical vitreous, the stripping of eventual epiretinal membranes, and finally an intraocular gas tamponade. During this procedure, peeling the internal limiting membrane (ILM) has been proven to increase closure rates and avoid postoperative reopening in several researches. In fact, even in large MHs more than 400 µm, the advantage of peeling off the ILM was highlighted by better anatomical closure rates. Nevertheless, some authors suggested that ILM peeling is not always essential, because it generates various side effects in retinal structure and function. Furthermore, the ideal amount of ILM peeling and the most effective strategies for removing the ILM are still subject of research. Different surgical modifications have been reported as alternatives to traditional peeling in certain clinical settings, including ILM flaps, ILM scraping, and foveal sparing ILM peeling. As regards large MHs, the introduction of ILM inverted flap appeared as a game changer, offering a significantly higher >90% closure rate when compared to traditional ILM peeling. Modifications to inverted ILM flap procedures have been claimed in recent years, in order to define the best area and direction of ILM peeling and its correlation with functional outcomes. Moreover, several innovations saw the light in the setting of recurrent MHs, such as ILM free flap transposition, inverted ILM flap combined autologous blood clot technique, neurosensory retinal flap, and human amniotic membrane (HAM) plug, claiming higher anatomical success rate also in those complex settings. In conclusion, the aim of this review is to report how the success rate of contemporary macular surgery has grown since the turn of the century, especially for big and chronic MHs, analyzing in which way ILM management became a crucial point of this kind of surgery.

19.
Diagnostics (Basel) ; 12(3)2022 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-35328280

RESUMEN

Intraoperative optical coherence tomography (iOCT) is a noninvasive imaging technique that gives real-time dynamic feedback on surgical procedures. iOCT was first employed in vitreoretinal surgery, but successively served as a guidance in several anterior segment surgical approaches: keratoplasty, implantable Collamer lens (ICL) implantation, and cataract surgery. Among all of those approaches, the unbeatable features of iOCT are fully exploited in anterior and posterior lamellar keratoplasty, and the purpose of this review is to focus on the advantages and shortfalls of iOCT in these techniques, in order to assess whether this technology could be a real step forward. In deep anterior lamellar keratoplasty (DALK), iOCT is useful to evaluate the needle depth into the corneal stroma, the big bubble dissection plane, and residual stromal bed, thus aiding the standardization of the technique and the reduction of failures. In Descemet stripping automated endothelial keratoplasty (DSAEK), iOCT allowed for clear visibility of fluid at the graft/host interface, allowing for immediate rescue maneuvers and granting the best graft apposition. In Descemet membrane endothelial keratoplasty (DMEK), iOCT can track the lenticule unfolding in real time and assess graft orientation even in severe hazy corneas, thus optimizing surgical times, as well as avoiding the use of potentially hazardous exterior markers (such as the "S" stamp) and preventing unnecessary manipulation of the graft. Overall, the role of iOCT appeared crucial in several complicated cases, overcoming the difficulties of poor visualization in a fast, non-invasive way, thus raising this approach as possible gold standard for challenging conditions. Further improvements in the technology may enable autonomous centering and tracking, overcoming the current constraint of instrument-induced shadowing.

20.
Am J Ophthalmol ; 240: 30-36, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35227693

RESUMEN

PURPOSE: To report the 1-year results of human amniotic membrane patch implantation for optic disc pit maculopathy. DESIGN: A prospective, consecutive, interventional study. METHODS: Eleven eyes of 11 patients affected by optic disc pit maculopathy associated with subretinal/intraretinal fluid were included in this single-institution study. A 25-gauge pars plana vitrectomy was performed in all cases, with an implant of a human amniotic membrane patch into the optic disc pit and air was injected as endotamponade. The primary study outcome was the subretinal and intraretinal fluid reabsorption. Secondary outcomes were visual acuity improvement and postoperative complications. RESULTS: Mean central retinal thickness gradually diminished from 512 ± 137 µm to 243 ± 19 µm, at the 12-month follow-up. The mean visual acuity improved from 20/80 at baseline to 20/32 at the 12-month follow-up. Complete fluid resorption occurred in 9 of 11 (81.8%) eyes and there was partial resorption in 2 eyes (18%). No subretinal fluid recurrence was observed during the 12-month follow-up. No intraoperative or postoperative complications were reported during the follow-ups. The amniotic membrane patch remained detectable inside the pit for the entire follow-up time. CONCLUSION: An amniotic membrane plug may be effective for improving optic disc pit maculopathy. All cases had an anatomical improvement and encouraging visual acuity recovery.


Asunto(s)
Anomalías del Ojo , Degeneración Macular , Disco Óptico , Enfermedades de la Retina , Amnios , Anomalías del Ojo/complicaciones , Anomalías del Ojo/diagnóstico , Anomalías del Ojo/cirugía , Estudios de Seguimiento , Humanos , Degeneración Macular/complicaciones , Complicaciones Posoperatorias/cirugía , Estudios Prospectivos , Enfermedades de la Retina/complicaciones , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Vitrectomía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...